Diagnostic X-ray machines from a 2 mA handheld to a 40 kW room system, with detectors, buckies and radiation protection. Built by Waymed Yamuna in Noida.
Get a quote




Seven families, from a 2 mA handheld to a 40 kW high-frequency room system. The dial reads tube current, then power. Drag the needle to jump.
2mAHigh frequency

5mAHigh frequency

10mALine frequency

100mALine frequency
300/500mALine frequency
5/8kWHigh frequency

15/32/40kWHigh frequency

Not sure which one? Tell us the room and the daily patient load.
Get a quote Every X-ray machine, with its own pageFour models have printed specification sheets. Everything below is copied from them; ask for the sheet of any other model with your quote.


| 100 mA FIXLine frequency | 300 mALine frequency | 15 kWHigh frequency | 40 kWHigh frequency | |
|---|---|---|---|---|
| Rating | 25 to 100 mA | 300 mA, 125 kVp | 250 mA, 40 to 125 kVp | 500 mA, 40 to 125 kVp |
| Output | 8 kW | 24 kW | 15 kW | 40 kW |
| Exposure | Timer 0.06 to 5 s | Timer 0.06 to 5 s | 1 to 200 mAs | 1 to 200 mAs |
| Generator | Full-wave rectified | Full-wave rectified | High frequency, microcontroller | High frequency, microcontroller |
| Controls | Digital display | Digital display | Feather-touch panel, digital kVp and mAs | Feather-touch panel, digital kVp and mAs |
| X-ray tube | XD-3 or imported | Rotating anode | Rotating anode, monoblock head | Rotating anode, monoblock head |
| Collimator | Manual | Manual | ||
| Tube stand | Fixed | Fixed and ceiling-free | Counter-balanced, floor and ceiling-free | Counter-balanced, floor and ceiling-free |
| Safety | Electronic overload protection | Electronic overload protection | Interlocks for earth fault, voltage, kVp, filament and heat; dual-action hand switch | Interlocks for earth fault, voltage, kVp, filament and heat; dual-action hand switch |
| Power | 230 V AC | 440 V | 230 V AC, single phase, ±10% | 440 V AC, three phase, ±10% |
Blank cells are not stated on that model's sheet.
High-frequency 15 and 40 kW: full specifications 100 mA FIX, CBM and SBM
A chest radiograph, developing on a view box as you scroll. Every model in the range exists to put a readable film like this on the box.
Digital imaging · capture
IGZO flat panel detector · 17 × 17 inch
One panel, wireless and wired in the same box. The BR-1717S is an imported IGZO detector that comes with acquisition software for a Windows console. It takes a full chest in one exposure and can trigger itself from the beam (automatic exposure detection), so it works without a cable to the generator.
BR-1717S DR flat panel detector: specificationsConnection
Scintillator
Same panel either way: unplug the cable and it works on Wi-Fi. CsI is the sharper, more dose-efficient choice; GOS is the economical one.
Ready. Press "Take an exposure" to see the panel at work.
Size
17 × 17 in · IGZO · wireless + wired in one box
One panel, two ways to connect
Runs on its battery and sends images over Wi-Fi: for trolleys, bedside work and portable units.
Plug in the Gigabit cable for a fixed bucky or table: no charging, no Wi-Fi to set up.
Digital imaging · print
Film printing software for CR and DR
Your CR or DR console prints to a Windows PC as if it were a film imager. Our software receives the film over DICOM and prints it at once on medical inkjet film, from 8 × 10 inch to A3. Two programs, both written by us: DIPROX and DICOM Print Pro 2.0.
DICOM print software: DIPROX and DICOM Print ProRule (AE title : port)
Printed pages left
Epson L130
Film size
Images per film
Pick a film size and press "Print a film". This PC has 2 pages of 13 × 17 left, so you'll see a recharge soon.
Recharge in minutes
Pay-per-film DICOM printing
Version 2.0 · the established print server
X-rays scatter off the patient, and the staff beside the table catch some of it every exposure. Bharat Rays makes the lead they wear and the barriers they stand behind.
Lead aprons and radiation protection: the full range
Inside the circle you see what an X-ray beam sees: the lead prints white because it stopped the beam; skin and cloth print dark.
Under the beam: chest and arms, shielded by the kit













Lead equivalence is the thickness of plain lead a garment matches. Ask which pieces come in which weight when you request a quote.